Composite Insulator Housing
Silicone rubber for sheds and housings requiring outdoor weather resistance, hydrophobic behavior, electrical insulation and resistance to tracking and erosion.
Factory-direct HTV/HCR silicone rubber grades developed for composite insulator housings, surge arresters, wire and cable insulation, cable joints, terminations and other demanding electrical applications.
Электронная почта: info@yakows.com · Include your application, process, target hardness and estimated quantity.
The correct silicone rubber grade depends on the final component, production process and required electrical and mechanical performance. Start with your application below.
Silicone rubber for sheds and housings requiring outdoor weather resistance, hydrophobic behavior, electrical insulation and resistance to tracking and erosion.
Power-grade compounds for molded housings and electrical components requiring dependable dielectric strength, dimensional control and outdoor durability.
High-strength silicone rubber compounds for extrusion or related processing, with high elongation, electrical insulation and flexible cable performance.
Material options for cable joints, terminations, stress-control components, cold-shrink parts and electrical sealing applications.
Our current highlighted grades cover outdoor insulator housings and high-performance wire and cable applications. Final selection should be based on your process, component design and test requirements.
Grades designed for composite insulator sheds, housings and electrical protection components. The series combines mechanical properties with breakdown field strength, volume resistivity and tracking-and-erosion performance.
Milky-white compounds with 40 Shore A typical hardness, high tensile strength and elongation for flexible wire, cable insulation and related electrical applications.
For composite insulator housings, sheds, surge arrester housings and related outdoor electrical components.
| Недвижимость | Единица | YK-3160D | YK-3160Z | YK-3160G |
|---|---|---|---|---|
| Твёрдость | Берег А | 65 ± 3 | 65 ± 3 | 60 ± 3 |
| Прочность на разрыв | кН/м | ≥10 | ≥10 | ≥12 |
| Прочность на разрыв | МПа | ≥4.0 | ≥4,5 | ≥5,0 |
| Elongation | % | ≥220 | ≥220 | ≥240 |
| Permanent Deformation at Fixed Extension | % | ≤4 | ≤4 | ≤4 |
| Плотность | г/см³ | 1.48 ± 0.03 | 1.46 ± 0.03 | 1.46 ± 0.03 |
| Breakdown Field Strength | кВ/мм | ≥20 | ≥21 | ≥22 |
| Tracking & Erosion Resistance (1A4.5 Class) | mm | ≤2.5 | ≤2.5 | ≤2.5 |
| Диэлектрическая проницаемость | — | ≤5 | ≤5 | ≤5 |
| Объёмное удельное сопротивление | Ом·см | 1 × 1014 | 2 × 1014 | 2 × 1014 |
Typical values, not guaranteed specifications. Test method, acceptance criteria and current TDS should be confirmed for each project.
For flexible wire and cable insulation applications requiring high elongation, tensile strength, tear strength and electrical performance.
| Недвижимость | Единица | YK-6141L | YK-6140L |
|---|---|---|---|
| Твёрдость | Берег А | 40 ± 3 | 40 ± 3 |
| Внешний вид | — | Milky White | Milky White |
| Plasticity | — | 165–205 | 160–200 |
| Плотность | г/см³ | 1.12 ± 0.03 | 1.12 ± 0.03 |
| Прочность на разрыв | МПа | ≥8.0 | ≥8.0 |
| Elongation | % | ≥700 | ≥700 |
| Permanent Deformation at Fixed Extension | % | ≤7.0 | ≤7.0 |
| Прочность на разрыв | кН/м | ≥25 | ≥30 |
| Linear Shrinkage | % | 3.2–3.5 | 3.2–3.5 |
| Диэлектрическая проницаемость | — | 2.5 | 2.8 |
| Объёмное удельное сопротивление | Ом·см | ≥2.0 × 1016 | ≥2.0 × 1016 |
| Breakdown Field Strength | кВ/мм | 22 | 22 |
Typical values, not guaranteed specifications. Confirm processing conditions, curing system and final component test requirements before selection.
Our technical discussion starts with the performance risks of the final electrical component rather than a generic material description.
Important for outdoor insulator and arrester housings exposed to electrical stress, contamination and moisture.
Supports electrical insulation performance in insulators, cable insulation and related high-voltage components.
High resistivity is essential for limiting leakage current through insulating silicone rubber materials.
Helps the compound withstand demolding, assembly, cable handling and mechanical stresses in service.
Especially important for wire, cable, cold-shrink parts and components that must accommodate movement or deformation.
Consistent plasticity, hardness and shrinkage help manufacturers control extrusion, molding and final dimensions.
A power-industry material supplier must support more than a product name. We organize the project around repeatable batches, technical files, application testing and clear communication with your purchasing and engineering teams.
The exact control plan can be aligned with your approved specification, sample validation requirements and purchasing process.

Raw materials and key inputs are checked before entering the production process.

Formula, mixing and batch records are controlled for repeatable processing behavior.

Relevant physical and electrical properties are checked according to the agreed control plan.

Approved material is packed, identified and prepared with the required order documents.
Before sample approval or mass production, the commercial and technical scope should be clear. The following support can be discussed for your project.
Selection based on insulator, arrester, wire, cable or cable accessory application and required performance.
Trial material can be discussed for processing evaluation and final component testing.
Hardness, color, formulation and performance targets can be reviewed with the technical team.
Current TDS, SDS, COA and available test documentation can be supplied for project review.
Packaging format, order quantity, lead time and export documents are confirmed during quotation.
Share your extrusion or molding process so the team can discuss grade fit and trial conditions.
A clear qualification process reduces material-selection risk and helps both teams move efficiently toward regular purchasing.
Send the final application, process, hardness, current material and target standards.
We compare your requirements with the YK-3160 or YK-6140 series and discuss alternatives.
Evaluate processing behavior and test the finished insulator, wire, cable or accessory.
After approval, confirm the specification, packaging, batch documents and delivery plan.
The highlighted insulator series includes YK-3160D, YK-3160Z and YK-3160G. Final selection depends on your molding process, component design and target physical and electrical performance.
YK-6141L and YK-6140L are the highlighted wire and cable grades. Both show 40 ± 3 Shore A hardness, ≥8.0 MPa tensile strength and ≥700% elongation in the supplied typical data.
Yes. Send the current grade or TDS, processing method, finished-component tests and any issues you want to improve. The technical team can use this information for an initial comparison.
Sample availability can be discussed for process trials and finished-component validation. Include the required quantity, application and delivery country in your inquiry.
Available project documents may include TDS, SDS, COA and relevant test or compliance files. Confirm the exact documents needed when requesting a quotation.
Custom requirements can be reviewed based on application, volume, processing method and performance targets. Development feasibility should be confirmed by the technical team.
No. They are typical values reproduced from the supplied product tables. The current official TDS, agreed specification and batch acceptance criteria should control the final order.
Please include the final component, production process, target hardness, test standard, current material, annual or trial quantity, country and any required documents.
Our team will review your application and help identify a suitable YK silicone rubber grade for technical evaluation.